Translations:Berechnungsschema/ Implementierung der Betriebsregeln/31/en

Aus TALSIM Docs
Version vom 21. Januar 2021, 18:59 Uhr von Ferrao (Diskussion | Beiträge) (Die Seite wurde neu angelegt: „In summary, a reservoir can have any number of uses. For each usage, there is a function dependent on the reservoir content, which must remain constant within…“)
(Unterschied) ← Nächstältere Version | Aktuelle Version (Unterschied) | Nächstjüngere Version → (Unterschied)

In summary, a reservoir can have any number of uses. For each usage, there is a function dependent on the reservoir content, which must remain constant within an external time step, but can be changed from time step to time step (time dependency). In addition, these functions can be scaled differently for each time step by external dependencies via factors. Prerequisite for the scaling are constant factors during the time step. The calculation process is independent of the time step, since it is decomposed according to the section crossings into arbitrarily many internal time steps. This means that the method is suitable for a wide variety of time intervals and produces results that are true to the volume. Thus, both a flood event with a time step of a few minutes and a long-term simulation with daily values or even larger time intervals can be used. The only decisive factor is that all discharge functions are defined over a sufficient number of grid points.