Aus TALSIM Docs
If more than one reservoir has an influence on the relevant control point or if, in principle, more than one storage facility is to be used to meet the demand, the required additional discharge is to be divided between the reservoirs in accordance with the corresponding regulations. A distinction must be made between the direct and indirect influences of a reservoir on the control point. A direct influence is present if a discharge can have a direct effect on the flow conditions at the control point, i.e. the natural flow between the reservoir and the control point can no longer be changed by regulation. If this is not the case, an indirect influence is given.