Version vom 26. November 2020, 14:46 Uhr von Ferrao (Diskussion | Beiträge) (Die Seite wurde neu angelegt: „If more than one storage facility has an influence on the relevant control point or if, in principle, more than one storage facility is to be used to meet dema…“)
(Unterschied) ← Nächstältere Version | Aktuelle Version (Unterschied) | Nächstjüngere Version → (Unterschied)

If more than one storage facility has an influence on the relevant control point or if, in principle, more than one storage facility is to be used to meet demand, the required external contribution is to be divided among the storage facilities in accordance with a corresponding regulation. A distinction must be made between direct and indirect influence of a storage facility on the control point. A direct influence is always present when the storage release can have a direct effect on the flow condition at the control point, i.e. between storage and control point the natural flow behaviour can no longer be changed by regulating interventions. If this is not the case, an indirect influence is given.